SPA Actuator with Intelli-Motion™ Technology Manual R00
May 2022
Page 30 of 48
bit6
RAM_Corruption n/a:bool
0
1
RAM corruption has occured.
Reset Required.
bit7 Motor_Overheated n/a:bool
0
1
Motor has reached maximum
temperature
bit8
Electronics_
Overheated
n/a:bool
0
1
Electronics have reached
maximum temperature
bit9-15
Unused -
0
0
Unused
INT
Unused (Pad)
50
INT:bits
FaultCommsBits
52
bit0
VFD_Initialization n/a:bool
0
1
The VFD could not be initialized
bit1
NVM_
Communications
n/a:bool
0
1
The NVM could not be
communicated with
bit2
NVM_Not_
Configured
n/a:bool
0
1
The NVM is not configured
bit3
NVM_Invalid_
Configuration
n/a:bool
0
1
The NVM is not properly/
completely configured
bit4
VFD_
Communications
n/a:bool
0
1
The VFD could not be
communicated with
bit5-15
Unused -
0
0
Unused
INT
Unused (Pad)
54
INT:bits
WarningBits
56
bit0
Parameters_Set_
to_Defaults
n/a:bool
0
1
Some parameters were set to
defaults
bit1
Reset_Required n/a:bool
0
1
A reset is required for full device
functionality
bit2-15
Unused -
0
0
Unused
INT
Unused (Pad)
58
FEEDBACK MESSAGE LEGEND
Control Feedback
Detailed Feedback
Current Settings ECHO
Static Values
SMART Actuator Implicit / I/O Messaging Data Structures
Actual Order/Type
Target to Originator (FEEDBACK MESSAGE)
60 Bytes/SINT Total
Byte Order: LSB
Data Type
Name
Eng Unit
Min
Max
Description
StartIndex(byte)