SPA Actuator with Intelli-Motion™ Technology Manual R00
May 2022
Page 4 of 48
1.5 Dimensions and Specifications
1.5.1 Envelope and Mounting Dimensions
1.5.2 Specifications
* Custom stroke lengths available. Contact the factory or a sales representative.
Mechanical Specifications
Dynamic Rated Load
1,500 lbs (6.7 kN)
Minimum Stroke Length*
6 in. (152 mm)
Maximum Stroke Length*
24 in. (610 mm)
Stroke Length Increments*
6 in. (152 mm)
Maximum Speed at Dynamic Rated Load
0.83 in./sec (21 mm/sec)
Duty Cycle Range at Dynamic Rated Load
xx% - 30%
Duty Cycle Range at Reduced Load
xx% - xx%
Operating Temperature Range
25° - 104°F (-4° - 40°C)
Ingress Protection Rating (static and dynamic)
IP54
Anti-Rotation Feature
Yes
Restraining Torque
215 in.-lbs (24.2 Nm)
Screw Type
ACME
Minimum Weight (6 in. Stroke Unit)
35 lbs (16 kg)
Maximum Weight (24 in. Stroke Unit)
41 lbs (19 kg)