SPA Actuator with Intelli-Motion™ Technology Manual R00
May 2022
Page 15 of 48
2.3 Analog I/O Adjustments
Figure 2-6: Selector Switches
Configure the Analog Input and Output using the selector switches on the User I/O board (behind the access cover on the
actuator). Select the input or output to be V (0 - 10V DC) or mA (4 - 20 mA). The input may be configured differently from the
output if preferred.
The Analog Output indicates the position of the actuator, scaled to the factory limits.
In “analog position” mode, the Analog Input may be used to select a target, or “Go-To” position for the actuator. To enable
this function, move the selector switch by “AIN” from “DIS” to “ENABLE.” When this function is enabled, the actuator will
attempt to move to the position selected by the Analog Input whenever the Enable digital input is asserted (+24V). (In this
mode, the Extend and Retract digital inputs are NOT used.)
shows the scaling for both the Analog
Input and the Analog Output.