temperature
sensor
has
reached the cooling or heating
temperature
(whether
the
temperature is higher or equal
to 77
DegF
in cooling mode).
4. Check whether the surface
of the condenser is too
dirty, it should be cleaned
when it is too dirty.
5.Check
whether
the
capacitance of the outdoor
motor and the fan is
damaged, it should be
replaced
when
it
is
damaged.
6.If the above items are
normal, the electric control
board should be replaced.
E5
PG motor
display
at off
state
flicker
5/7 SEC
display
at off
state
no
feedback
signal of
indoor fan
1.Check whether two sets of
plugs on the outlet end of
the motor have loosed
from the socket of the