Service Manual
32
The system blocked slightly
Check
capillary
tube,
strainer etc. repair or
replace them.
The outdoor temperature is below
20DegF
The A/C can
’
t defrost
Replace this sensor or
move the sensor to the
thickest position of frost
The indoor or outdoor motor
speed is lower
Replace this fan motor
The compressor suction or
venting capability is very poor
Replace the compressor
4-way valve slight mixes up
Let the four-way valve
moving
continually.
Replace the four-way valve
if it can’t move
The capillary valve has been
blocked.
Replace the capillary valve
04 Cannot heat.
The fan doesn’t run (motor or
capacitor of fan failed, Poor
contact for the line of capacitor,
Check. Repair and replace.