operate properly. Wall units throw air approximately 15’ (9 & 12,000 Btu/h units) and 25’
(18 & 24,000 Btu/h units)
Use the templates provided to locate the unit on the wall and to center the
refrigerant connection hole –
DuctlessAire
recommends a 3” wall penetration to ease
mounting of the unit.
2.6
Outdoor Unit Positioning
Ensure that a minimum distance of 6” behind the unit, and 24” in front of unit is
maintained; otherwise the condenser airflow will be affected.
Ensure adequate access for service and repair is provided. The easiest access to the unit
can be obtained by removing the top cover to the condensing unit. All valve and
electrical connections are on the RHS of the Outdoor unit when looking at the condenser
fan.
3.
Installation Tips
Tools required for installing a
DuctlessAire
Mini Split
10” or 12” Crescent wrenches (x 2)
Small Electrical Screwdriver
Tool to help knockout the cable entry holes
Refrigerant Gauges and 5/16” Gauge Adaptor
Vacuum Pump and Vacuum gauge
Digital Refrigerant scale to weigh in extra R410A for long line set lengths
Temperature measurement device
Multi Meter
3.1
R410a Refrigerant
R410a refrigerant has similar temperatures to that of R22, however as well documented
the pressures of R410A are approximately double that of R22. In addition to this the
compressor oil used with R410A is extremely hydroscopic i.e. attracts water; therefore
several precautions must be taken when installing R410A refrigerant units.