The Temperature sensing probe should be securely attached on or adjacent to a return bend
on the condenser coil that measures 100 DegF in normal operation. In practice this
works out to be the 3
rd
Return bend down from the top of the coil. Securely strap the probe
to the bend or tube and insulate to ensure accurate temperature sensing.
Wiring
Wiring should be in accordance with the diagrams on the following pages,
DO NOT
deviate from the wiring shown, if in doubt please call Technical Support for assistance.
Please note on Heat Pump units the bypass connection must be wired from the Reversing
Valve to the ICM controller to ensure that the Outdoor fan operates at full speed in the
Heat Pump Heating mode.