![DuctlessAire DA-09 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/ductlessaire/da-09/da-09_service-manual_2537953025.webp)
Service Manual
25
These are:
1) Minimize the time that the system piping is open to the atmosphere. Avoid
problems with a clean installation of refrigerant lines. Make sure that the flares are
free of burrs and seat correctly.
2)
DuctlessAire
does not recommend any brazing of refrigerant line sets.
3) Do not install Sight Glasses or Filter Driers in the interconnecting Line Set.
4) Pressure tests the system with dry Nitrogen or other dry gas.The system must be
put
into a deep vacuum (200 Microns minimum),
DuctlessAire
recommends a minimum
of
45 minutes evacuation using the double evacuation process, breaking the original
vacuum with dry Nitrogen, then re-evacuating prior to opening the service valves as
the best method of ensuring a perfectly dry system.
5) In order to prevent confusion with what type of refrigerant is used in the system
DuctlessAire
uses a 5/16” Schrader connection on the Suction line to attach a gauge
set to.
Therefore an adaptor is required to connect to a standard US gauge set.
It is always a good practice to insulate the flare nuts to prevent loosening as the system
operates; this is especially recommended for Heat Pump units due the changes in the
temperatures seen at the service connections when the units operate in heating and then
enter defrost.
3.2
Electrical Wiring Connections
These
systems are ALL POLARITY SENSITIVE to the power supply, even the 208/230V
units, it is VITALLY IMPORTANT that the wiring from Outdoor to Indoor unit is point
to point, with the wire leaving one terminal on the Outdoor units landing in the same
numbered or lettered terminal on the Indoor unit.