rosin joint on the electric
control board, if there is
any, it should be repaired.
3.When the 1 and 2 are both
normal, then the components
or integrated circuit is
damaged, the electric control
board should be replaced.
E3
display
at off
state
flicker
3/5 SEC
display
at
on/off
state
coil
temp. sensor
fault
1.Check
whether
the
resistance of the sensor is
normal,
when
it
is
abnormal
the
sensor
should be replaced.
2.Check whether there is short
circuit or open circuit in the
wire of the sensor, and
whether the plug is connected
well, whether there is welding
off or rosin joint on the
electric control board, if there
is any, it should be repaired.
3.When the 1 and 2 are both