DResearch – User Manual TeleObserver MR3180
2011-02-03
18
2.3
Significance of the status LEDs
On the front of the unit there are four coloured LEDs which indicate the current status of the device.
At any time you can determine the current status of the device from the colour codes. We recommend
that you print out the following table and keep it with your service documents.
LED
State
Description
off
device is switched off
green
device is ready for operation
orange
device is booting or shutting down
Status
(state of the device)
red
Error – contact the service department!
off
device is not recording
green
actively recording into the ring archive (normal)
orange
actively recording into the alarm archive (alarm event)
orange
flashing
HD will be deleted and adopted by the device in 30 seconds
HD
(recording)
red
hard disk is not available or could not be recognised/adopted by the
device
no recording on the hard disk
other errors
off
no connection between PC and device
green
active data transmission, connection between PC and device
orange
not busy
Link
(LAN-connection)
red
Error – no communication
off
archives cannot be recognised (fault)
green
0% - 60% of the capacity full
orange
> 60% - 80% of the capacity full
Archive
(archive fill level)
red
> 80% - 100% of the capacity full
The codes listed here could be changed by the manufacturer. If in doubt contact your system
integrator or the manufacturer.