DResearch – User Manual TeleObserver MR3180
2011-02-03
51
Field
Description
Indicate alarm
recordings by relays
If alarm video sequences are to be recorded from at least one camera, select the
relay to be activated.
The relay remains activated as long as there is active alarm recording including
during the post-alarm period.
Relays which have already been switched by detector activations cannot indicate
any alarm recording and are therefore not included in the list of options.
Indicate system failure
1 by relays
Select the relay to be activated if a system fault occurs.
The system event which is to be treated as fault 1 can be determined in the
System events list.
Relays which have already been switched by detector activations cannot indicate
any system fault and are therefore not included in the list of options.
Indicate system failure
2 by relays
Select the relay to be activated if a system fault occurs.
The system event which is to be treated as fault 2 can be determined in the
System events list.
Relays which have already been switched by detector activations cannot indicate
any system fault and are therefore not included in the list of options.
IBIS device type
Select with which IBIS telegrams the system shall communicate with the IBIS
Master.
The system works conform to the IBIS standard VDV300.
The system can be configured as ‘Cancelation device’, ‘Stop announcement’ or
‘Display’ (telegrams 020/120, 030/130 or 070/170). The IBIS standard does not
provide an own device type for video systems.
Address
Insert here the video systems address within the IBIS bus. Make sure that these
addresses will not be awarded twice! Inform about the current configuration and
the specific oft he used IBIS system.
List of system events
Shows all system events.
Mark the appropriate event by double clicking to assign a system fault.