3.1.1.2
System :: Time
Caution: If you reset the time of the MR3140 unit backwards, and you then save the new
configuration, all the video footage which is now in the future according to the new time,
is automatically deleted!
Field
Description
Time Zone
Select a time zone from the listing.
The valid properties for that time zone are displayed in the fields below.
Time
Update time (while
sending the
configuration)
When the configuration is sent the time of the unit is synchronised with that of the
service PC.
External time sync
Regular synchronisation of the unit’s time with that of an external source.
Synchronization
Source
Here you select the external source for synchronising the device time.
For this the following conditions have to be fulfilled:
A GPS receiver is connected and configured.
The MR3180 is linked to the IBIS bus.
Synchronize time every
… Hour(s)
This is used to determine the synchronisation cycle.
Maximum difference …
Minute(s)
Enter here the maximum time deviation (in minutes) from the synchronisation
source.
If when compared, the time deviation is greater than this value then
synchronisation takes place. After that the device starts new.
Set your time zone and make
the settings for automatic time
synchronization in this dialog.