DResearch – User Manual TeleObserver MR3180
2011-02-03
46
3.1.1.11 Connectors :: Network
Field
Description
Gateway
Enter the IP address of the gateway.
Note: The IP addresses of the recorder and gateway have to be in the same
network sector.
The gateway enables communication and data transmission between computers
which are in different networks or in a linked external communication system.
Enter the IP address of the unit if all the connections to be made to the MR3140
are in its network sector or no gateway is available.
List of the network
interfaces
All the network adapters installed in the MR3180 are shown here.
Click and highlight to display the parameters of a network interface.
IP address
Shows the IP address of the highlighted network adapter.
Net mask
Shows the current network mask.
Boot protocol
Not used
Each device in a network has to get a unique address - otherwise there will be IP address conflicts,
a connection to the device is then not possible.
The device always books two IP addresses. The second IP address is automatically assigned and
is one number higher than the configured first IP address.
In the example above, the device then uses the IP addresses 10.32.82.3 and 10.32.82.4 - Configure
the network adapter of the outstation with at least two IP addresses difference!
If a connection is impossible, please empty the ARP cache of the computer using the
arp –d
command
(through console).
The network configuration of the device is
determined in this dialogue box. Changes to the
settings can only be made by authorised specialists
with thorough network knowledge.
Incorrect settings may mean that the device can no
longer be reached!
Standard IP: 192.168.0.1 (and 192.168.0.2)