DResearch – User Manual TeleObserver MR3180
2011-02-03
57
4.4
Overheat protection: temperature shutdown level of the system
The system is equipped with an automatic overheating protection which ensures that damages caused
by overheating will be excluded. If the device’s internal temperature reaches a value of +55°C the
system shuts down controlled to protect the disk and further system components.
Please note that the internal temperature of the system can be up to 15°C higher than the ambient
temperature (because of the heat generation of the components).
Note therefore essential the mounting instructions in this document. Avoid installations where
heat can build up. Select the installation place so that adequate air circulation is provided and the
developing heat can be derived through the heatsinks of the device.
Deactivating of the 55°C overheat protection isn’t recommended but possible. Here is the
shutdown level at a value of 70°C – not 55°C. For r easons of security the configuration of the
temperature shutdown level isn’t possible through the configuration settings. The relevant
settings can be done during an update of the systems with the update tool.
Please note that the operation of the system components (e.g. HDD) is recommended by their
respective manufacturers only up to 55°C.
4.5
Default configuration for factory reset
By starting a reset via the web interface of the system or if the system can’t load the actual
configuration because of an error the fallback configuration will automatically be loaded. It’s possible
to define the factory or the system (the customer specific) configuration as fallback configuration.
Actual system configuration:
During a reset a copy of the actual configuration of the system will be loaded. This ensures that the
individual system settings will be maintained after reset, too.
Factory configuration:
During a reset the standard configuration – delivered by the manufacturer – will be loaded. At this
previously made settings in the system will be lost. The only exception: The IP address of the device
will not be reset – so that the system afterwards can be achieved without reconfiguring the service PC.
Please note that the fallback configuration can only be defined during an update with the
DResearch update tool or by loading a specific configuration file. This can be made available by
the manufacturer on request.