Version 5.01 – July 2012 / SW Version: 2012.06.12Errore. Per applicare Nadpis 1 al testo da visualizzare in questo punto, utilizzare la scheda Home.
© DRC Srl 2012
64/102
6. Functions of Analog Output
A brief description of analog output functions is presented in the following table:
GATE 1
GATE 4
AUOT1
Voltage
Value mapping
ON
not ES+AUX
self-test sine burst 1 MHz
1.35V ±1V
ON+AUX
not ES+AUX
Gate1 echo flank position
0 to 2.7V
Gate1 [- ---- -]
Max
value if
no echo
ON+A/TTL not ES+AUX
Gate1 echo flank position
0 to 2.7V
Gate1 [- ---- -]
any
ES+AUX
S-echo position
0 to 2.7V
Gate1 [- ---- -]
GATE 1
GATE 2
AOUT2
Voltage
Value mapping
ON
any
Undefined
(used internally for ver.C)
4.1V
ON+A/TTL
any
Gate1 eco logic TTL output
0V / 4.7V
no echo / echo
ON+AUX
OFF
Gate1 echo amplitude
0V to 4.1V 0 % - 100 % screen
ON+AUX
Thickness
Gate1-Gate2 Thickness
0V to 4.1V
0 to BSCAN_MAX
TTL OUT
Voltage
Value mapping
Firmware since Jan 2012 Sync pulses with PRF freq.
0V / 4.7V
Positive pulse on
cycle start, 10
µ
s
duration, falling
edge matches TX
pulse
6.1 Analog Output of Thickness Measurement
Analog output of measured thickness is enabled, when the GATE 1 is switched to the
ON+AUX mode, and GATE 2 is switched to any thickness measuring mode.
Signal with voltage corresponding to thickness measured in each cycle is present on
AOUT2 output (LEMO Analog Output – see 1.7 and 2.1) as follows:
-
minU=0mm;
-
maxU=[BSCAN MAX]mm – value BSCAN MAX, which had been set in BSCAN
menu – see 4.5;
-
if thickness had not been measured, there is maxU on the output.
NOTE: The cable with appropriate connector may be ordered as option.