dormakaba ED50 Installation Instructions – Fine cover
Appendix A
Parameter
Value
range
Units
Factory
setting Description
Castor angle for double doors
Primary door with astragal, angle active door must open before secondary door opens.
51
0 - 30
°
30
Hinge clearance
1. Clearance between hinges is critical for the calculated door angle.
2. It may only have a small effect but the clearance can be adjusted in extreme cases to
improve accuracy.
3. Factory setting is 3 * 10, 30 mm, 1 3/16".
4. With CPD doors, setting must be changed to a negative value. A learning cycle is then
required as system creates an angle table as a function of the set parameters.
52
±
5
*10
mm
3
*10
±
3/16
*10
inches
26.1.1 Driving parameters detail.
Overhead concealed mode (OHC):
Activation of permanent open via
night-bank input (v2.2)
53
0 - 1
0
0
Function disabled.
1
If night-bank signal is longer than 3 seconds, operator changes to permanent open
mode.
Overhead concealed mode (OHC):
Adjustable behavior after blockage / hold
open (v2.2)
53
0 - 1
0
0
Standard behavior (3 x restart).
1
Manual mode after blockage.
Reversing after trigger of approach side
safety sensor / opposite hinge side in
operating mode hd=1 (v2.2)
55
0 - 1
0
0
Standard behavior, stop.
1
Reversing