44
ED50
01-2020
DL4615-001
dormakaba ED50 Installation Instructions – Fine cover
Chapter 12
12.5.3 Install conduit box (option).
TIPS AND RECOMMENDATIONS
115 Vac terminal block is secured
to mounting plate by M3 x 25
Phillips head screw.
• Screw must be loosened to
allow conduit box tabs to slide
into mounting plate slots.
• Screw is then threaded into
conduit box mounting hole and
tightened.
1. Loosen M3 x 25 Phillips head screw.
2. Slide conduit box tabs into slots in
bottom of mounting plate until hole in
conduit box lines up with hole in
mounting plate.
3. Thread M3 Phillips head screw into
conduit box mounting hole and tighten
screw.
CAUTION
Terminal block M3 screw torque.
Tighten M3 screw to a torque of
5 - 7 in-lb.
• Insure screw is threaded into
conduit box mounting hole.
4. Mounting plate assembly is ready for
installation.
Fig. 12.5.5 115 Vac terminal block mounting
Fig. 12.5.6 Conduit box installed on
mounting plate
1
115 VAC terminal
block
2
Ground terminal
5
M3.5 screw
6
115 Vac plug to
operator
L
115 Vac
N
Neutral
G
Ground
1
115 VAC terminal
block
2
Ground terminal
5
M3.5 screw
6
115 Vac plug to
operator
7
Conduit box DX3501
7.1
Conduit box
mounting hole
1
2
5
6
L
N
G
5
6
2
7
7.1
1
2
6
7
1
3
4
5
Fig. 12.5.7 PC power cord wiring kit assembly (option)
1
Power cord
3
Cord grip
4
Conduit box
5
120 Vac label