114
ED50
01-2020
DL4615-001
dormakaba ED50 Installation Instructions – Fine cover
Appendix E
114
ED50
Appendix E - Wiring diagrams
E1.1 DX4604-21C Key Switch Panel with RJ45 connector
Fig. E1.1.1 Key switch panel
DX4604-21C
Fig. E1.1.2 Key switch panel wiring diagram
Reference Para. 14.7 for RJ45
cable connection.
RED
WHT
BLK
GRN
BLK
ORG
57 57a
X10
X8
X4
X5
X6
15 17
11
3 1
13 3
1
42
3
3 1
1
41
35
33
32
3
30
3
34
31
1 6 3 1
4 4a
99 98 97
3 B A 1
3
43
64
63
62
1G
3
X9
X1
X7
X3
+2
4
0V
0V
+2
4
Swing
side
0V
0V
Test
Sign
al
Approach
side
Sign
al
Test
+2
4
0V
Feedback
contact
0V
0V
Door
status
35
33
32
3
30
3
34
31
X1
0V
0V
O
ff
A
ut
omati
c
Exi
t Only
P
ermanen
t Ope
n
WHT
GRN
ORG
RED
BLK
22 AWG stranded (7 x 30)
Length = 80 inches
AUTO CLOSE OPEN
EXIT ONLY
E1.1.1 Key switch panel option.
Set parameter PS to 1.
CAUTION
Key switch panel option.
Program switch wired to ED50
terminal board.
1) Parameter
PS
(Program
switch type) must be set to 1.
Reference: Appendix A,
Parameter detail and Para. 19.3,
Set Parameter PS.
2) Internal program switch
connector must be disconnected
from operator.
Reference Para. 20.3 item 4