106
ED50
01-2020
DL4615-001
dormakaba ED50 Installation Instructions – Fine cover
Appendix C
106
ED50
Parameter name
Description
Setting
Setting code
0, low active
(function on)
1, function off
Inp. Night - bank
r/o
Status of Night -bank
input X9, 6 and 1
0
1
Inp. OPEN
r/o
Status of program
switch permanent
OPEN input X1, 34
0
1
Inp. PART OPEN
r/o
Status of program
switch PARTIAL OPEN
input X1, 33
0
1
Inp. EXIT ONLY
r/o
Status of program
switch EXIT ONLY input
X1, 32
0
1
Inp. AUTO
r/o
Status of program
switch AUTO input
X1, 31
0
1
Inp. OFF
r/o
Status of program
switch OFF input X1, 30
0
1
Inp. Sfty pull side
r/o
Status of safety sensor,
hinge side input X5, 15
0
1
Inp. Sfty push
side
r/o
Status of safety sensor,
opposite hinge side
X5, 11
0
1
Inp. Activ extern
r/o
Status of external
activation sensor X6, 41
0
1
Inp. Activ intern
r/o
Status of internal
activation sensor X6, 42
0
1
Inp enable
operator
r/o
Status of Emergency
close input X6, 4 and 4a
0
1
Inp. smoke
detector
r/o
Status of smoke
detector input
X9, 3 and 1
0
1
Inp. lock status
r/o
Status of locking device
input X3, 43 and 3
0
1
Locking status
locked
Parameter name
Description
Setting
Klemme 1G
Clamp X3, 1G and 3,
24 V out
Opening width
r/o
Displays opening angle
( .. ) °
Cur. door position
r/o
Displays current door
angle
( .. ) °
Amb. temp.
r/o
Displays ambient
temperature
( .. ) °C
Amb. max
r/o
Displays maximum
ambient temperature
( .. ) °C
Motor temp.
r/o
Displays motor
temperature
( .. ) °C
Motor temp max.
r/o
Displays maximum
motor temperature
( .. ) °C
Com 1
r/o
Com 1 connection
( .. )
C.5.1 Diagnostics