66
ED50
01-2020
DL4615-001
dormakaba ED50 Installation Instructions – Fine cover
Chapter 19
Step 1
Press
Press
PRG
greater than 3 s to enter
program mode, AS parameter
displayed.
If no change required, go to step 7.
Step 2
Press
Displays "00" , factory setting.
Step 3
Press
"00" starts flashing.
Step 4
Press
Scroll to select parameter value.
"1" shown as example.
Step 5
Press
Saves value entered. Display stops
flashing.
Step 6
Press
Returns to Installation type parameter.
19.2.1 Set parameter AS, installation type.
Installation type
Parameter
value
Parameter description
0*
Pull arm with track, wall mounting on swing
(hinge) side.
1
Push arm, wall mounting on approach (opposite
hinge) side.
2
Push arm with track, wall mounting on approach
(opposite hinge) side.[Application specific]
*
Factory setting
19.2 Set configuration parameters
Fig. 19.2.1 4 button keypad,
2 digit display
3
Four button
keypad
4
Two digit display
Step 7
Press
Scroll to
rd
parameter.
Step 8
Press
Displays "00" , factory setting.
Step 9
Press
"00" starts flashing.
Step 10
Press
Scroll to select parameter value.
"6" shown as example.
Step 11
Press
Saves value entered.
Display stops flashing.
Step 12
Press
Returns to reveal depth parameter.
19.2.2 Set parameter rd, reveal depth.
Configuration parameter settings continue on next
page..
TIPS AND RECOMMENDATIONS
Reference Chapter 15 for reveal depth
parameter values.
4
3
> 3s Reset
< 3s Quit
> 3s
PRG
< 3s
LEARN
Fact-Setup
> 3s
> 8s