62
ED50
01-2020
DL4615-001
dormakaba ED50 Installation Instructions – Fine cover
Chapter 18
18.1 Parameters
Step 1
Press right button greater than 3 s to
enter program mode.
Step 2
Press up or down button to scroll through
parameters until desired parameter is
displayed.
Step 3
Press right button to display current
parameter value.
Step 4
Press right button again to enable
editing of value, display will start
flashing.
Step 4
Press up or down button to select
desired parameter value.
Step 5
Press right button to save selected
value. Display stops flashing.
Step 6
Press left button to return to selected
parameter.
Step 7
Press up or down button to scroll
through parameters until next desired
parameter is displayed.
Step 8
Press left button for a minimum of 3 s
to exit program mode.
Fig. 18.1.1 dormakaba handheld terminal
18.1.2 Configuration parameters
Configuration parameters (Para. 18.1.5) are set during
first commissioning (Chapter 19).
• Reference Para. 18.1.7 for configuration parameter
detail.
18.1.3 Driving parameters
Driving parameters can be set once first commissioning
has been completed.
• Reference Para. 18.1.6 for a list of driving parameters.
• Reference Appendix A for driving parameter detail.
1
Program switch,es,
close position
18.1.4 Changing parameter values.
1. Set program switches to the CLOSE position
2. Use 4 button keypad as outlined in Steps 1 through 8
to view or change parameter values.
Fig. 18.1.2 Program switches
Fig. 18.1.3 4 button keypad,
2 digit display
2
2 digit display
5
4 button keypad
18 Parameters
18.1.21 Firmware version and updates.
• Operator firmware version is displayed during first
commissioning. Reference Chapter 19.
• dormakaba handheld can be used to check operator
firmware version and to perform firmware updates.
Reference Appendix C. dormakaba handheld, or
dormakaba handheld manual.
> 3s Reset
< 3s Quit
> 3s
PRG
< 3s
LEARN
Fact-Setup
> 3s
> 8s
2