69
MicroController Control System
Troubleshooting
PROBLEM 16
Display = “EE”, no lift truck drive operation.
POSSIBLE CAUSE
Static Return to Off (SRO) circuit activated by
improper operation sequence; Direction switch defect;
Accelerator linkage not fully released;
Accelerator control defect; Logics defect.
CHECKS
Check for SRO by release of accelerator, release
park brake, move the direction lever to neutral,
reselect direction and press the accelerator.
No change
Lift Truck Operation OK
Run “Quick-Diagnostics” to find
faulty circuit or component.
If no faulty component is found,
replace logics.
Inform operator of correct start–up procedure.
Also, that the direction lever must be left
in neutral when leaving the truck.