5
MicroController Control System
Specifications
Specifications
Component Measurements
H2 / HP Technical Specifications
Motor Types : ................................................................................................... DC Series Tr DC Series Pump
Power ratings : Traction .....................................................................................................................................13.5kW
Pump ........................................................................................................................................11.0kW
Supply Voltage : .................................................................................................................................................... 48V
Traction Motor Switching frequency : .................................................................................................................18kHz
Pump Motor Switching frequency : ....................................................................................................................18kHz
Temperature range : ............................................................................................................................-30˚C to + 40˚C
Maximum Controller temperature : .......................................................................................................................85˚C
Current Measurements
Component
Meter
Scale
Meter Positive
(+) Test Lead
Meter Negative
(-) Test Lead
Desired Indication
CONTACTOR COILS (resistance Indication)
Line, Bypass
200
X
Y
90 to 110 ohms
Directional, Regen
200
X
Y
60 to 80 ohms
48V SYSTEM CURRENT VALUES (AMPS)
Maximum Traction Motor Current
Maximum Pump Motor Current
650
± 5 %
600
± 5 %
Содержание B20S-3