65
MicroController Control System
Troubleshooting
PROBLEM 12
Park brake switch circuit defect.
POSSIBLE CAUSE
Wiring defect; Park brake switch defect; Logics defect.
CHECKS
Disconnect DD or DE connector. Release park brake lever.
Check continuity from DD-2 to DE-1.
Continuity
No continuity
Replace park brake switch.
Check continuity from DD-2 of wire #4 to
terminal of park brake switch.
Continuity
No continuity
Check continuity of wire #71.
Continuity
No continuity
Repair or replace wire.
Repair or replace wire.
Replace logics.