110
MicroController Control System
Testing And Adjusting
Description of SET OPTIONS Functions
<DRIVE CONTROLLER>
Function
Option
Meaning
BYPASS
Bypass contactor adopted.
WEAKENING
NOT AVAILABLE
2. SPEED CONTROL
-
NOT AVAILABLE
Activates the check that reads the battery voltage in standby.
ON
When the residual charge is less than 10%, the maximum
current is reduced by 70% and the LED blinks continuously.
OFF
No low battery charge alarm.
ON
Activates anti-rollback function.
OFF
No anti-rollback
Braking active at the moment of accelerator pedal release with
increment of the braking current by means of the brake pedal.
OFF
No regenerative braking at accelerator pedal release.
RUNNING
Hour meter only active when running.
KEY ON
Hour meter active with the key on.
Interrupt function for the truck when the key switch turn on
SEAT
without an operator on the seat or while no one is on the seat
during 6 sec. under the key on.
HANDLE
NOT AVAILABLE
8. SOFT BRAKING
-
NOT AVAILABLE
9. AUX FUNCTION
-
NOT AVAILABLE
<PUMP CONTROLLER>
Function
Option
Meaning
1. BYPASS CONTACTOR
-
NOT AVAILABLE
Activates the check that reads the battery voltage in standby.
ON
When the residual charge is less than 10%, the maximum
current is reduced by 70% and the LED blinks continuously.
OFF
No low battery charge alarm
RUNNING
Hour meter only active when running.
KEY ON
Hour meter active with the key on.
4. MAIN CONTACTOR
-
NOT AVAILABLE
5. AUX FUNCTION
-
NOT AVAILABLE
3. BATTERY CHECK
1. BYPASS CONTACTOR
4. ANTIROLLBACK
5. RELEASE BRAKING
6. HOUR COUNTER
7. SAFETY SWITCH
ON
2. BATTERY CHECK
3. HOUR COUNTER
Содержание B20S-3