23
MicroController Control System
Systems Operation
DRIVE CONTROLLER
Description of Connectors
NOTE :
“NORMAL VOLT” ; Battery connected, key switch and seat switch and parking brake switch are closed.
PIN
FUNCTION
DESCRIPTION
NORMAL VOLT
DA-1
-LED
ALARM LED NEGATIVE
0
DA-2
+LED
ALARM LED POSITIVE
12V
DB-1 PCLRXD
SERIAL RECEPTION POSITIVE
HIGH/LOW
DB-2 NCLRXD
SERIAL RECEPTION NEGATIVE
HIGH/LOW
DB-3 PCLTXD
SERIAL TRANSMISSION POSITIVE
HIGH/LOW
DB-4 NCLTXD
SERIAL TRANSMISSION NEGATIVE
HIGH/LOW
DB-5 GND
CONSOLE SUPPLY NEGATIVE
0
DB-6 +12V
CONSOLE SUPPLY POSITIVE
12V
DB-7 SPEED REDUCTION INPUT FOR SPEED REDUCTION (ACTIVE HIGH)
0
DB-8 -
-
-
DC-1 CPOT
CENTER OF ACCELERATOR POTENTIOMETER
0
DC-2 NPOT
NEGATIVE SUPPLY TO ACCELERATOR
0
DC-3 PPOT
POSITIVE SUPPLY TO ACCELERATOR
12V
DD-1 KEY
INPUT FROM KEY SWITCH
B (+)
DD-2 CM(+)
COMMON RUNNING MICROSWITCHES
B (+)
DE-1 HAND BRAKE
INPUT FOR HAND BRAKE MICROSWITCH
B (+)
DE-2 D/TEMPERATURE
DRIVE MOTOR TEMPERATURE INPUT(NORMAL CLOSED)
B (+)
DE-3 FWD
FORWARD MICROSWITCH INPUT
0
DE-4 SEAT
SEAT SWITCH INPUT
B (+)
DE-5 PEDAL BRAKE
PEDAL BRAKE MICROSWITCH INPUT
0
DE-6 REV
REVERSE MICROSWITCH INPUT
0
DE-7 ENABLE
INPUT FOR ACCELERATOR PEDAL MICROSWITCH
0
DE-8 -
-
-
DE-9 -
-
-
DG-1 COMMON
POSITIVE FOR CONTACTOR COIL
0
DG-2 BACKWARD
NEGATIVE FOR BACKWARD CONTACTOR COIL
0
DG-3 BYPASS
NEGATIVE FOR BYPASS CONTACTOR COIL
0
DG-4 REGEN. BRAKE
POSITIVE FOR REGEN. BRAKE CONTACTOR COIL
0
DG-5 FORWARD
NEGATIVE FOR FORWARD CONTACTOR COIL
0
DG-6 REGEN. BRAKE
NEGATIVE FOR REGEN. BRAKE CONTACTOR COIL
0
Содержание B20S-3