MicroController Control System
Troubleshooting
PROBLEM 1
Central Vehicle Monitoring System (CVMS) does
not work, with no lift truck operation.
POSSIBLE CAUSE
Battery polarity not correct on control panel;
Key fuse open circuit; Key switch defect;
Logics defect.
Push horn buttton to close horn switch.
Horn work
Horn does not work
Make correction to cables.
Disconnnect battery and check the horn
fuse for continuity.
Continuity
No continuity
Check for shorts and
replace fuse.
Replace key switch or repair broken
wire #5 between key switch and DD-1.
Close key switch. Measure voltage on DD-1
Battery
Less than
Voltage
Battery voltage
Measure voltage on horn (wire #90) with
depressing the horn switch.
Check continuity the negative wire of horn
Battery
Less than
Voltage
Battery voltage
Repair or replace
open wire.
Replace logics.
Replace horn or
check the battery.
CHECKS
With battery connected, check control panel battery connections for correct polarity.
Positive battery connected to line fuse and negative battery connected to B - on controller.
If correct
If not correct