112
MicroController Control System
Testing And Adjusting
ADJUSTMENTS : ADJUST BATTERY (Drive and Pump Controller)
Using this function it is possible to calibrate the internal voltmeter to a fine level. lt is necessary to input the battery
voltage value after measurement using an external calibrated digital voltmeter.
Procedure showing how to carry out ADJUST BATTERY operation by console.
1. Opening HEADING.
2. Press Top Left & Right Buttons to enter CONFIG. MENU.
3. The Display will show : SET MODEL
4. Press ROLL UP BUTTON until ADJUSTMENTS Menu
appears.
5. ADJUSTMENTS appears on the display.
6. Press ENTER to go into the ADJUSTMENTS Menu.
7. The display will shows SET BATTERY TYPE.
8. Press ROLL UP or ROLL DOWN buttons until desired
OPTION appears.
9. ADJUST BATTERY appears.
10. Press PARAM. or SET buttons in order to increase
or decrease respectively. Set the valus read by an external
calibrated digital voltmeter.
11. Battery value appears on the display.
12. Press OUT to exit the Menu.
13. Confirmation request appears.
14. Press ENTER to accept the changes, or press OUT
if you do not accept the changes.
15. ADJUSTMENTS Menu appears.
16. Press OUT. Display now show the Opening HEADING.
KEYBOARD
CONFIG. MENU
SET MODEL
CONFIG. MENU
ADJUSTMENTS
SET BATTERY TYPE
48V
ADJUST BATTERY
56.0V
ADJUST BATTERY
48.6V
ARE YOU SURE?
YES = ENTER NO = OUT
CONFIG. MENU
ADJUSTMENTS
+
-
DISPLAY
HP P.STD DHX.XX
48V 600A XXXXXX