User manual 250/400 OLED
Rev.: SG-20220516
Page 75 of 79
FlexxPump 250 / 400 OLED
User manual
5. Mounting the upper housing of the drive unit of
the FP 250/400 OLED.
Place the disassembled upper housing on the
FP 250/400 OLED and press it onto the drive unit.
Fasten the upper housing to the drive unit by
turning the retaining ring clockwise.
Grip the retaining ring on the outside right and
left for easier loosening, as shown with the pink
arrows.
The retaining ring must engage noticeably when
turned and be completely tightened.
Carry out the work according to the above description.
If a message was shown in the display before the cartridge was changed, the message now
disappears. A separate acknowledgement is not required.
After completion of this work, the FP 250/400 OLED automatically returns to the last active mode
(ON or OFF) before the work.
If the empty cartridge level (note E1) has been reached during a pumping cycle, the cycle will be
automatically interrupted and automatically continued after completion of the work.
9.3. Disposal
Observe the relevant national valid regulations for the disposal of the FP 250/400 OLED and empty
or opened cartridges.
For disposal, observe the respective safety data sheets and disposal instructions for the individual
components.
It is not possible to refill empty lubricant cartridges.