User manual 250/400 OLED
Rev.: SG-20220516
Page 21 of 79
FlexxPump 250 / 400 OLED
User manual
What you should know about operating and setting the FP 250/400 OLED:
The FP 250/400 OLED is suitable as a multi-point lubricator for one or two lubrication points.
However, depending on the specific application, FP 250/400 OLED can also supply a limited number
of lubrication points reliably and cleanly with lubricant. Accessories from the manufacturer (e. g.
distributors or progressive distributors) can be connected to the FP 250/400 OLED. If necessary,
changes must be made to the FP 250/400 OLED settings to ensure safe and reliable operation.
The FP 250/400 OLED is a cycle controlled lubricator , which works time-based via the integrated
microelectronics and is connected to a 24V DC power supply. The FP 250/400 OLED cyclically delivers
a defined quantity of lubricant from the cartridge to the outlet. Three operation modes can be selected.
The operating mode
„Setting lubrication cycle duration“
enables the setting of the number of
lubrication strokes (C) and a lubrication cycle duration (h) in hours. Lubrication cycle durations (h)
between 1...240 hour(s) and lubrication strokes (C) between 1...30 can be set.
The operating mode
„Setting emptying time“
enables the setting of the cartridge emptying time in
months. Emptying times between 1...36 month(s) and lubrication strokes (C) between 1...30 can be
set. The pump calculates the lubrication cycle duration automatically.
Alternatively, the FP 250/400 OLED can also be integrated into a control system (PLC) and
commanded and controlled via this in „
pulse control mode“
, see Chap. 8.
A lubrication cycle SZ thereby consists of one (1) pump cycle PZ and a pause time t
P
. The pump
cycle PZ can consist of a minimum of one (1) and a maximum of thirty (30) lubricating strokes C. In
this case, the up to thirty (30) lubrication strokes C per outlet are performed directly one after the other.
After the end of the pump cycle PZ, the FP 250/400 OLED pauses until the pause time t
P
has elapsed
and automatically executes the next lubrication cycle SZ after the set lubrication cycle duration t
SZ
has
elapsed.
00
11
tt
LLuubbrriiccaattiioonn
ooppeerraattiioonn
SSZZ
11
SSZZ
22
SSZZ
33
…
SSZZ
11335500
EEm
mppttyyiinngg ccyyccllee ooff aa ccaarrttrriiddggee EEZZ