6.3.5. Activate the Filling-menu
The filling command enables you to trigger a defined multiple dispensing at the FP 250/400 OLED.
A pump cycle PZ with a total of 40 lubrication strokes C is initiated with the activation. This function
enables you to pre-fill connected accessories (tubes, distributors, etc.) with the lubricant contained
in the lubricant cartridge, especially during the initial commissioning of the FP 250/400 OLED. The
process can be interrupted manually at any time.
The FP 250/400 OLED is switched on and there is no fault or error.
Remove the activation and programming key from the upper housing of the FP 250/400 OLED and
place it on the action area.
Hold the activation and programming key on the action area. The double circle appears in the
bottom right corner. Leave the activation and programming key on the action area until
Filling
appears
in the display. Remove the activation and programming key from the action area until Filling appears in
the display. The double circle disappears.
The confirmation hook appears; the display and the hook flash twice for visual confirmation.
If you do not want to cancel the process: Reattach the activation and programming key in the
opening provided for this purpose on the upper housing of the FP 250/400 OLED.
The FP 250/400 OLED delivers 40 strokes of lubricant.
If you want to cancel the operation: Move the activation and programming key to the action area
during the pump cycle PZ and wait until the STOP symbol appears in the display. Remove the
activation and programming key from the action surface as long as STOP is shown in the display. The
double circle disappears.
The confirmation hook appears; the display and the hook flash twice for visual confirmation.
The FP 250/400 OLED cancels the filling function. In addition, the number of complete lubrication
strokes is shown in the display.
Observe the back pressure values shown in the display if they are of interest to you.
If you use the Filling menu in the operating mode Setting emptying time, this will have a shortening
effect on the set emptying time.
The Filling menu can only be reached from the ON mode (FP 250/400 OLED switched on). If you
have activated the Fill command, you will automatically return to ON mode.