𝑡𝑡𝑡𝑡
𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃
=
𝐶𝐶𝐶𝐶 ∗ 𝑡𝑡𝑡𝑡
𝐶𝐶𝐶𝐶
+ (
𝐶𝐶𝐶𝐶 −
1)
∗ 𝑡𝑡𝑡𝑡
𝐸𝐸𝐸𝐸
𝑡𝑡𝑡𝑡
𝑃𝑃𝑃𝑃
=
𝑡𝑡𝑡𝑡
𝑆𝑆𝑆𝑆𝑃𝑃𝑃𝑃
− 𝑡𝑡𝑡𝑡
𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃
User manual 250/400 OLED
Rev.: SG-20220516
Page 44 of 79
FlexxPump 250 / 400 OLED
User manual
6.3.4.2. Operating mode Setting Emptying time
The different parameters can be calculated as follows:
General information:
250 cm³ cartrdige
400 cm³ cartridge
FP 250/400 OLED with 1
outlet
=
𝑡𝑡𝑡𝑡
𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸
∗
30,5
𝑑𝑑𝑑𝑑 ∗ 24ℎ ∗
𝐶𝐶𝐶𝐶
16
6
7
=
𝑡𝑡𝑡𝑡
𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸
∗
30,5
𝑑𝑑𝑑𝑑 ∗ 24ℎ ∗
𝐶𝐶𝐶𝐶
2
667
FP 250/400 OLED with 2
outlets
=
𝑡𝑡𝑡𝑡
𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸
∗
30,5
𝑑𝑑𝑑𝑑 ∗ 24ℎ ∗
2
∗ 𝐶𝐶𝐶𝐶
16
6
7
=
𝑡𝑡𝑡𝑡
𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸
∗
30,5
𝑑𝑑𝑑𝑑 ∗ 24ℎ ∗
2
∗ 𝐶𝐶𝐶𝐶
2
667
Simplified calculation of the
lubrication cycle duration t
SZ
[h] depending on the selected cartridge and
FlexxPump type:
Term/Parameter
Shortcut
Value
Number of lubrication strokes per pump cycle
and outlet
C
adjustable, 1 ... 30
Lubrication stroke time
t
C
predefined, 7s ... 17s
Relaxation time
t
E
predefined, 2s
Pause time
t
P
calculable
Pump cycle
PZ
–
Pump cycle duration
t
PZ
calculable
Lubrication cycle
SZ
–
Lubrication cycle duration
t
SZ
calculable
Emptying time
EZ
–
Emptying time of a cartridge
t
EZ
adjustable, 1 ... 36
Содержание FlexxPump 250 OLED