User manual 250/400 OLED
Rev.: SG-20220516
Page 34 of 79
FlexxPump 250 / 400 OLED
User manual
6.3.4. Set operating mode and cartridge size
The Settings menu allows changing general parameters of the FlexxPump setting as well as changing
specific parameters of the selected operating mode. The general parameters include adjusting the
operating mode and changing the cartridge size of the FP 250/400 OLED used. You can switch
between the operating modes
Setting Lubrication Cycle Duration
, Setting
Emptying Time
and
Pulse Control
. This chapter explains how to select the operating mode and change the cartridge
size between 250 cm³ and 400 cm³. The explanation of how to change specific parameters within the
different operating modes and their explanation is given in the following chapters.
Procedure:
The FP 250/400 OLED is switched on and there is no fault or error.
Remove the activation and programming key from the upper housing of the FP 250/400 OLED and
place it on the action area.
Hold the activation and programming key on the action area. The double circle appears in the bottom
right corner. Leave the activation and programming key on the action area until
Settings
appears in
the display. Remove the activation and programming key from the action area until Settings appears in
the display. The double circle disappears.
The confirmation hook appears; the display and the hook flash twice for visual confirmation.
Chap. 6.3.4.1
Chap. 6.3.4.2