User manual 250/400 OLED
Rev.: SG-20220516
Page 56 of 79
FlexxPump 250 / 400 OLED
User manual
7.2. Output signals – Time control
Output signal (PIN 4)
Meaning
Description
0,5 Hz-Square wave signal,
permanent
Note E1
Empty cartridge
The integrated microelectronic of the
FP 250/400 OLED is equipped with an
automatic counter which counts the
number of lubrication strokes. If this signal
is present, the FP 250/400 OLED will not
deliver any lubricant! Remedial measures
can be found in Chap. 9.2.
low, permanent
FP 250/400 OLED is
switched off
Error E2
Error E3
Error E4
A permanent low level (0V) at PIN 4
means that the FP 250/400 OLED is either
switched off or – if it is switched on – there
is an error. The error must be read on the
display of the FP 250/400 OLED (chap.
6.4). The FP 250/400 OLED does not
deliver lubricant!
high, permanent
FP 250/400 OLED is
operation correctly
A permanent high level (+24 V DC) at PIN
4 means that the FP 250/400 OLED is
working correctly and that there is no error.
The FP 250/400 OLED operates according
to the settings made and delivers lubricant
from the cartridge to the outlet accordingly.
The present FP 250/400 OLED provides three output signals in the time control via the electrical
interface. Basically, the output signals can only be sampled and must not be subjected to inductive
load or low ohmic load. This enables – in addition to the optical indication via the display on the
FP 250/400 OLED – also the status control from a distance.