background image

Instruction

 Manual

Series E7 

Metering Pumps

For file reference, please record the following data:

Model No: 
Serial No: 
Installation Date: 
Installation Location: 

When  ordering  replacement  parts  for  your  LMI  Pump,  please  include  the  complete 
Model Number and Serial Number of your unit.

Replaces same of Rev. C 10/97

1718.D 3/06

201 Ivyland Road

Ivyland, PA  18974 USA

TEL: (215) 293-0401

FAX: (215) 293-0445

http://www.Imipumps.com

1718.D_306.indd   1

4/4/06   1:21:14 PM

For more information, please call 877-742-2878 or
visit www.burtprocess.com

Summary of Contents for E7 Series

Page 1: ...rdering replacement parts for your LMI Pump please include the complete Model Number and Serial Number of your unit Replaces same of Rev C 10 97 1718 D 3 06 201 Ivyland Road Ivyland PA 18974 USA TEL 2...

Page 2: ...sories 5 Output Adjustment Initial Approximation 5 Procedure for On Site Volumetric Calibration E7 in Internal Mode 6 Procedure for On Site Volumetric Calibration E7 in External Mode 6 2 0 Troubleshoo...

Page 3: ...area that is convenient to both solution injection point and electrical supply LMI Series E7 metering pumps have corrosion resistant housings but should not be subjected to continuous high temperatur...

Page 4: ...is little or no resistance back pressure the velocity of the pumped fluid will be so great as to cause over pumping Be cause of this characteristic back pressure equal to approximately 25 psi 1 7 Bar...

Page 5: ...After installation is complete and an initial approximation setting has been made the pump should be calibrated and the stroke frequency and or stroke length settings adjusted F Nominal output and pre...

Page 6: ...lume of 500 ml or more C Turn pump to internal mode with speed knob set at 100 and operate until air is exhausted from suction line and pump head D Turn pump off and note solution level in graduated c...

Page 7: ...ump by turning the inner section of the knob counter clockwise Position the outer section of the knob so that the pointer aligns with zero on the nameplate Push down on the outer section of the knob a...

Page 8: ...ockwise rotation until motion stops Reset knob by grasping the knob and pulling it towards you Pry the yellow cap off of the knob Place the knob on a flat surface Using needle nose pliers squeeze the...

Page 9: ...iquifram setting is not correct restart pump then screw the Liquifram in or out Always stop pump electrically when checking Liquifram setting Repeat procedure if necessary After Liquifram is set prope...

Page 10: ...10 3 0 EXPLODED VIEW 28 29 29 30 27 26 25 24 23 31 33 41 34 32 42 37 1718 D_306 indd 10 4 4 06 1 21 49 PM...

Page 11: ...5839 Spacer 3 0 1 28 E7 10973 Shaft Seal 1 29 E70 E71 E72 E73 10598 Screw 10 24 S S 4 E74 10598 Screw 10 24 S S 8 30 E7 25452 Label 1 31 E7 31542 Nameplate 1 32 E70 E71 32465 Stroke Dial 1 E72 32466 S...

Page 12: ...on Roy All Rights Reserved Printed in USA Specifications subject to change without notice Replaces same of Rev C 10 97 1718 D 3 06 201 Ivyland Road Ivyland PA 18974 USA TEL 215 293 0401 FAX 215 293 04...