Installation and 

Operating Instructions

WARNING: 

Failure to follow these instructions and comply with all applicable 

codes may cause serious bodily injury and/or property damage.

The installation of this product should be carried out by a person knowledgable 

in swimming pool plumbing requirements following the installation instructions 

provided in this manual.

Please pass these instructions on to the operator of this equipment.

Davey pH Peristaltic Pump

Model: M5138R

Summary of Contents for M5138R

Page 1: ...serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installation instructions provided in this manual Please pass these instructions on to the operator of this equipment Davey pH Peristaltic Pump Model M5138R ...

Page 2: ...ube on the Injection Valve 10 4 Connecting the power and pool pump to your pH Controller 11 5 Commissioning and Operation 12 5 1 Calibration Procedure 12 5 2 Settings 13 5 2 1 Adjustment of the Set point 13 5 3 Operating Principle 14 6 Maintenance 14 6 1 Replacement of the Peristaltic Tube 14 6 2 Maintenance of the Peristaltic Tube 15 6 3 Maintenance of the Electrode 15 6 4 Controller Winterising ...

Page 3: ...t were not allowed for in its design In case of doubt please refer to the details listed within this document or contact your point of purchase or Davey Water Products for further information The manufacturer of this product will not be liable for damage deriving from improper erroneous or unreasonable use of the pump 1 2 Risks After unpacking the pump make sure that it is completely sound In case...

Page 4: ...iquid Dosage To avoid risk from contact with hazardous liquids or toxic fumes always adhere to the notes in this instruction manual and wear protective clothing gloves goggles overalls Follow the instructions of the dosing liquid manufacturer Check the hydraulic part of the pump and use it only if it is in perfect condition Use only the correct materials for the tubing valves and seals to suit the...

Page 5: ...s of PVC Cristal tube C Electrode pH Probe Protective Cap D Foot filter E Injection valve F Clamp DN50 x 2 G Buffer solution pH7 H Screws Masonry plugs for wall mounting I Inline electrode holder J Shutter washer K Controller mounting bracket Pool Size Recommended Water Acid Dilution Ratio Volumes for a Suitable 20 Litre Container Water parts Acid parts Water Litres Hydrochloric Acid litres Up To ...

Page 6: ... Press CAL allows calibration of the pH to pH 7 0 when using the buffer solution pH7 3 Current value of pH being measured eg 7 0 4 pH unit of measurement and indicates that the device must inject acid 5 On off button to turn on the device When held down primes the pump Fig 2 1 2 3 4 ...

Page 7: ...00mm between the probe C and the injection valve E The injection valve E must be placed last in the pipework hydraulic installation In the case of an installation with redox and pH regulation it is advised to put the two sensors side by side and the pH injection before chlorine injection to minimise the risk of scale deposition on the chlorine injection For optimal service life of your peristaltic...

Page 8: ...he bracket of the pump Remove the bracket on the pump by sliding it down Locate the bracket in the space chosen and mark the holes Drill the holes as required 3mm for timber walls 6mm for masonry walls Fix the bracket to the wall Slide and secure pump into the bracket Fig 4 ...

Page 9: ...g of Injection Valve Fig 5 Fig 7 Fig 6 Fig 8 O ring A nut Put Teflon tape on threads Next Pierce the top wall of the pipe work through the clamp Ø 8mm for the injection valve Ø 14 mm for the electrode pH probe This assembly is fixed on the pipe work E ...

Page 10: ... the probe has been constructed as indicated in Fig 9 tighten the probe nut without crimping the probe body Push the probe approximately 20mm into the pipe work so that the probe tip is approximately halfway into the pipe work Connect the probe lead to the BNC terminal on the pump Fig 10 The hydraulic hose is placed in the same way on the foot filter and on the pump 1 Slide the tube through the nu...

Page 11: ...o it operates during the preset filtration time cycles If your pool pump is plugged into your Chlorinator Step 1 Remove the pump plug from the Chlorinator pump power socket Usually at the bottom of the Chlorinator Step 2 Plug the 3 pin male piggy back plug on your pH pump into the Chlorinator pump power socket Step 3 Plug your pool pump into the female piggy back socket on the back of the pH pump ...

Page 12: ...it for reuse at the time of winterising 2 Rinse the probe in tap water for at least 20 minutes Steps Before carrying out the calibration of the probe remember to Stop the filtration pump Close the isolation valves if fitted Remove the probe from the probe holder Put the shutter washer fig 12 in to close off the hole in the probe holder Open the isolation valves if fitted Turn on the filtration pum...

Page 13: ...pleted It is now ready to measure the pH of your pool 3 Next immerse the probe in the pH 7 solution stir around in bottle and leave it in the solution being careful not to touch the probe or the cable 4 After a period of at least one minute the stabilized value is displayed Press the CAL button until the display shows CAL flashing then release The quality of the probe reading is then briefly displ...

Page 14: ...perational time period proportional to the required dosage demand That is why the device often has the pump off This is normal Adjust the pH slowly to preserve the natural quality of your water After 30 minutes without pressing the keys the backlight turns off to save energy A short press on SET or CAL turns it on again 6 Maintenance 6 1 Replacement of the Peristaltic Tube Follow steps 1 to 9 as s...

Page 15: ...ill deposit on the sensing element of the probe To overcome this problem it is advisable to use the cleaning solution for electrode pH probe and redox AYACSOLNET01 and follow the procedure on the suppliers bottle 6 4 Controller Wintering Only in areas where subzero temperatures are experienced During winterising you must protect the peristaltic tube It is advisable to remove the peristaltic tube a...

Page 16: ...onnector 1 Change the probe 2 Change the buffer solution 3 Change over the probe Alarm Alr Err If the pH is lower than pH 5 or above pH 9 this alarm will be displayed and dosing will be stopped Adjust your water parameter manually so that it comes back to the required value of these parameters Total alkalinity TH hardness pH The dosing pump will restart as soon as the pH reading If trouble persist...

Page 17: ...30V 240V 5 Kit Roller 6 9mm holder Front cover hose 6 9 6 Peristaltic hose 6 9mm 7 Injection valve 8 pH electrode 9 Probe holder 10 Shutter 11 Foot filter 12 Clamp DN50 13 Tube 4x6 PVC Cristal 14 Buffer solution pH7 NOT SUPPLIED Storage liquid for probe pH RX 100mL NOT SUPPLIED Cleaning solution for probe pH RX 250mL 7 8 9 10 11 12 13 14 ...

Page 18: ...nty decision in writing and if found to be invalid the customer must organise collection of the product at their expense or authorise its disposal If the claim is found to be valid Davey will at its option repair or replace the product free of charge The Davey warranty is in addition to rights provided by local consumer law You are entitled to a replacement or refund for a major failure and compen...

Page 19: ...y Australia 3179 Ph 613 9730 9124 Fax 613 9753 4248 Email export davey com au Website davey com au NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 334 Email sales dwp co nz Website daveynz co nz EUROPE ZAC des Gaulnes 355 Avenue Henri Schneider 69330 Meyzieu France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu MIDDLE...

Page 20: ...y com au Website davey com au NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 334 Email sales dwp co nz Website daveynz co nz EUROPE ZAC des Gaulnes 355 Avenue Henri Schneider 69330 Meyzieu France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu MIDDLE EAST Ph 971 50 6368764 Fax 971 6 5730472 Email info daveyuae com Web...