IMPORTANT INFORMATION 
MANDATORY  INSTALLATION  CONDITION:  THE  PREMISES  WHERE  THE  PUMP  IS  INSTALLED 
MUST  BE  PROTECTED  BY  AN  RCD  (SAFETY  SWITCH) 

  DO  NOT  INSTALL  PUMPS  WITHOUT 

THIS PROTECTION 

 

All parts shown are WaterMarked & certified for Potable Water 

 

Fittings may differ from the image shown 

 

Do not adjust the PRV, warranty is void if adjusted  

 

Read and follow the instructions in the pages following  

WMK Licence: WM-022109 
 
Australian Standard:  WMTS-477  

IMPORTANT: if installing close to a wall or other fixture, use barrel-
union connections to allow removal if ever required. 

 

Содержание RainPro RC550

Страница 1: ...LLATION CONDITION THE PREMISES WHERE THE PUMP IS INSTALLED MUST BE PROTECTED BY AN RCD SAFETY SWITCH DO NOT INSTALL PUMPS WITHOUT THIS PROTECTION All parts shown are WaterMarked certified for Potable Water Fittings may differ from the image shown Do not adjust the PRV warranty is void if adjusted Read and follow the instructions in the pages following WMK Licence WM 022109 Australian Standard WMTS...

Страница 2: ...Page 2 Ascento Group Australia P 1800 807 604 E csv ascento com au WaterMark Quality System Doc RQS 1059 ...

Страница 3: ...Page 3 Ascento Group Australia P 1800 807 604 E csv ascento com au WaterMark Quality System Doc RQS 1059 ...

Страница 4: ...Page 4 Ascento Group Australia P 1800 807 604 E csv ascento com au WaterMark Quality System Doc RQS 1059 ...

Страница 5: ... sealed VERY well Use 15 wraps of thread seal tape on the male thread DO NOT USE glue unless you are CERTAIN that you will not drip glue inside the pump 7 Glue or other substances dripped inside the pump voids warranty Do NOT fit threaded fitting to the pump then glue pipe to that fitting as glue will drip inside the pump Glue the fitting and allow it to dry BEFORE attaching the threaded fitting I...

Страница 6: ...RY REQUIREMENTS FOR ALL INSTALLATIONS For any installation of pumps supplying irrigation you must fit an 18L or larger pressure tank Set tank air pressure RPS036 set air pressure to 250kPa RPS050 set air pressure to 350kPa 17 IMPORTANT NOTICE RE THE STOPPING FUNCTION In some situations the pump will cycle a few times after each use THIS IS NOT A WARRANTY FAULT it is a normal function of the intern...

Страница 7: ...the checking in daylight hours 9 6 to 8 are not applicable for a submersible pump with float switch it will stay off until the tank fills again 10 If it is dry for a long time no rain it is best to turn the power off to the pump at the power outlet 11 A First flush diverter or similar device must be installed to prevent debris from entering the tank or a filter screen through which all the incomin...

Страница 8: ... tank or a filter screen through which all the incoming water passes before entering the tank NO WARRANTY if the pipe is less than 25mm INTERNAL DIAMETER Step 2 IF THE PUMP HAS A FLOAT SWITCH ensure it can move freely and wont get stuck against the side of the rainwater tank or baffles inside the tank Step 3 Attach Rainwater supply to the RM4000 3 Valve as shown in the diagram Step 4 Connect Disch...

Страница 9: ...INGS TO CHECK BEFORE YOU CALL FOR SERVICE WARNING SAFETY FIRST TAKE PRECAUTIONS Before servicing a pump always shut off the power supply and then make sure you are not standing in water and that there is no risk of electrical shock If the pump is direct wired to the electrical circuit contact a licensed electrician to disconnect it TROUBLESHOOTING CHECKLIST Before you call for service or repair pl...

Страница 10: ...is installed backwards arrow on valve should point in direction of flow have the installer fix this 3 Discharge shut off valve ball valve gate valve may be closed open the valve 4 Impeller or volute openings are fully or partially clogged or it might be blocked with debris disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technicia...

Страница 11: ...es which is not a pump warranty have the valves disassembled and cleaned by a licensed Plumber 2 Filter between pump and house if fitted is blocked change the filter cartridge 3 Inlet filters on the inlet of the Toilet Cisterns and Washing Machine are blocked turn the pump and the mains water off disconnect the hoses and clean the filters 9 I have done all above what do I do now If you have follow...

Страница 12: ...or replacement warranty replacement or upgrading The installation must NOT be constructed in such a manner that specialized tools or paid tradespersons or external paid contractors are required to be engaged in order to remove and or replace and or refit the pump therefore all pumps must be installed using barrel union connections to facilitate easy servicing or replacement If the rainwater tank i...