8. Input and output signals – External control (PLC)
8.1. Pin assignment – External control (PLC)
To command the FP 250/400 OLED via an external control (PLC), it is necessary to switch the
FP 250/400 OLED to pulse control mode in the Settings menu (chap. 6.3.4).
The FP 250/400 OLED operates in pulse control mode as a pulse-controlled lubrication system only if
unalterable control signals of defined length are transmitted from the PLC to the FP 250/400 OLED via
PIN 2. The FP 250/400 OLED signals the respective condition to the PLC via high/low levels, which
must be tapped at PIN 4, and thus enables comprehensive control of the various conditions. For the
integration of the FP 250/400 OLED into an external control system, one input and one output each must
be provided on the control side.
PIN Assignment
Colour
1
+24 V DC
brown
2
Input Signal PLC
FP 250/400 OLED
white
3
Ground
blue
4
Output Signal FP 250/400 OLED
PLC black
Type: M12x1 female connector; 4-pin, A-coded
PIN-Assignment-external control (PLC):
DANGER
Machine elements that are not lubricated can cause failures resulting in
serious injury or death.
To operate the FP 250/400 OLED via an external controller (PLC) in pulse
control mode, a program corresponding to the communication protocol must be
created in the PLC.
After sending a control signal, the response signal of the FP 250/400 OLED
must be waited for, evaluated and interpreted in order to prevent an uncontrolled
failure of the FP 250/400 OLED.