ms every two seconds to indicate that it is a digital equipment call, not voice.
OFF = I.D. Tone Disabled.
[6] I.D. Tone Frequency
ON = 2100 Hz I.D. Tone
OFF = 1300 Hz I.D. Tone
[7] DLS Window Options
ON = One Time 1-hour user Enabled DLS Window.
The User Enabled DLS Window is 1 hour in length and will be closed after a successful hang-up
from a downloading call.
OFF = Full 6-hour User Enabled DLS Window.
The User Enabled DLS Window is 6 hours in length and remains open after a successful hang-up
from a downloading call.
Note: this option also determines the length of the DLS window available on power up.
[8] FTC Bell Options
ON = Bell on FTC when armed.
If a Failure to Communicate Trouble is generated while EITHER Partition is armed, the Bell output
will sound for the length of Bell time-out or until the system is disarmed.
OFF = FTC Trouble only when armed.
If a Failure to Communicate Trouble is generated while the panel is armed, the Bell output will not
sound but the keypad buzzer will sound trouble beeps until a key is pressed.
[703] Delay Between Dialing Attempts
For standard (force) dialing, the panel will go off-hook, search for dialtone for 5 seconds, hang-up for 20 seconds, go
off-hook, search for dialtone for 5 seconds, then dial. If there is no initial handshake recognized within 40 seconds,
the panel will hang up. This programmable timer adds a delay before the next call is attempted.
[704] Dialtone Search Time
This is the maximum amount of time the panel searches for dial tone.
Valid Entries are 001-255 seconds. Default is 005
[705] Dialtone Duration
This is the minimum amount of tone required before the panel qualifies it as dialtone.
Valid entries are 004-255 (x25 milliseconds). Default is 004.
[706] Lower Dialtone Cutoff
This is the lower dialtone cutoff frequency.
Valid entries are 050-250. Default is 250.
Notes: The value entered does not correspond to the frequency value. A table is required (value X = frequency Y)
This value MUST be greater than that programmed in Section [707].
[707] Upper Dialtone Cutoff
This is the upper dialtone cutoff frequency.
Valid entries are 050-250. Default is 062.
NOTE: The value entered does not correspond to the frequency value. A table is required (value X = frequency Y)
This value MUST be less than that programmed in Section [706].
[708] Delay Between Force Dialing Attempts
This is the time the panel waits between the first dialing attempt and the force dial
attempt. Valid Entries are 001-255 seconds. Default is 020.
[709] Busy Tone Duration