Digital Security Controls Ltd.
60
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
[405] ANSWERING MACHINE DOUBLE-CALL TIMER
Default
060
I__II__II__I
(Valid entries are 001-255 seconds)
[406] NUMBER OF RINGS TO ANSWER ON
Default
000
I__II__II__I
(Valid entries are 000-255 rings)
[499][Installer Code][499]
INITIATE PCLINK
•
ENTER [499] [INSTALLER CODE] [499]
INTERNATIONAL PROGRAMMING
[700] AUTOMATIC CLOCK ADJUST
Default
60
I___II___I
(Valid entries are 00-99)
[701] FIRST INTERNATIONAL OPTIONS CODE
Default
Option ON
Option OFF
OFF I___I
Option 1
50 Hz AC
60 Hz AC
OFF I___I
Option 2
Time Base is Internal Crystal
Time Base is AC Line
OFF I___I
Option 3
AC/DC Arming Inhibit Enabled
AC/DC Arming Inhibit Disabled
OFF I___I
Option 4
All System Tampers Require Installer Reset
All System Tampers follow Restore
OFF I___I
Option 5
6-Digit User Access Codes
4-Digit User Access Codes
OFF I___I
Option 6
Busy Tone Detection Enabled
Busy Tone Detection Disabled
OFF I___I
Option 7
High Current Battery Charge
Standard Current Battery Charge
OFF I___I
Option 8
For Future Use
[702] SECOND INTERNATIONAL OPTIONS CODE
Default
Option ON
Option OFF
OFF I___I
Option 1
Pulse Dialing Make/Break Ratio is 33/67
Pulse Dialing Make/Break Ratio is 40/60
ON I___I
Option 2
Force Dialing Enabled
Force Dialing Disabled
OFF I___I
Option 3
Land Line Test Tx Interval is in Minutes
Land Line Test Tx Interval is in Days
OFF I___I
Option 4
1600 Hz Handshake
Standard Handshake
OFF I___I
Option 5
ID Tone Enabled
ID Tone Disabled
OFF I___I
Option 6
2100 HZ ID Tone
1300 Hz ID Tone
OFF I___I
Option 7
One Time 1-Hr User Enabled DLS Window
Full 6-Hr User Enabled DLS Window
OFF I___I
Option 8
Bell on FTC when armed
FTC Trouble only when armed
[703] DELAY BETWEEN DIALING ATTEMPTS
Default
001
I___II___II___I
(Valid entries are 000-255 seconds)
[801] NOT USED
[802] AUDIO INTERFACE
[10]
Port Assignments, Zones 1-8
•
Enter the nearest Intercom Port Number (01= Main Unit, 02= Remote Sounder, 00 = Not Used)