Digital Security Controls Ltd.
12
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
5.2.13 Function Key Programming in ESCORT Programming
vii
Function Key programming has been moved out of the main panel and into Section [807], Sub-section [000]. This
has been done in order to keep the corresponding programming in the ESCORT section of the product. This
allows the desired functionality to be obtained without major impact to the existing architecture of the software.
5.2.14 New Logs
viii
In order to support the new Module Placement functionality, a new log has been implemented for:
Event %1D5
Module Placement Test Unsuccessful
8.0 Functional Description of…
8.1 Standard Features
TWO MINUTE BYPASS ON POWER UP
When power is first applied to the system, all zones will be bypassed for two minutes. This is to allow time for the
devices to “settle” without causing false alarms. If after 2 minutes any zones are still unrestored, they will be
detected as open and will generate the respective alarm sequence, if applicable.
ALARMS ANNUCIATED WHILE ARMED
Zone Alarm conditions will be annunciated on all the WLS9000 by Verbally annunciating them as they occur.
This also occurs for 24 Hour alarms while disarmed.
ACCESS CODE REQUIRED TO CANCEL AUTO ARMING
An access code must be entered to cancel (postpone) the Auto-Arm sequence during the 1-minute Auto-Arm
Warning time.
HARDWIRED ZONE LOOP RESPONSE TIME
The hardwired zone loop response time is fixed at approximately 500ms.
Note: The WLS9000 hardwired zones require a single 5.6K EOL resistor.
TIME-OUTS
The general system time-out for Installers mode is 20 minutes. If the unit is left in Installer’s for twenty minutes
without a keypress, it will return to its base menu.
SILENT EXIT DELAY IF STAY ARMING
If the system Stay armed using any of the following methods, all audible exit features (keypad buzzer) that are
enabled will be silent for the exit delay time. Bell Squawk on Exit Delay will also be silent if Home or [*][9] Armed.
Bell Squawk on Arm/Disarm will still sound regardless of how the panel is armed/disarmed.
[*][9][Access Code]
[Stay Arm Function Key (Option 03)]
[No Entry Arm Function Key (Option 05)]
SPECIAL ENTRY IF ALARM IN MEMORY
If any entry delay begins on the system and there are alarms in memory, the entry tone shall sound a pulsing
tone for the entire entry delay (as per Entry Delay Urgency).
SWINGER SHUTDOWN RESET
If Swinger Shutdown is enabled on the system, all counters will be reset when the system time changes from
23:59 (11:59 PM) to 00:00 (12:00 AM) OR any time the system is armed (expiration of the exit delay).
ENTRY DELAY URGENCY