Digital Security Controls Ltd.
24
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
A Recent Closing transmission shall be sent if an alarm occurs within 2 minutes of an exit time
expiration. The Recent Closing report will be sent for the first alarm only.
This reporting code is sent to the Alarm & Restoral call direction group of the System.
[F], [A], [P] Alarms & Restorals
If enabled, these reporting codes will be sent if the keys are used to generate manual alarms.
These reporting codes are sent to the Alarm & Restoral call direction group of Partition 1.
Zone Tampers & Tamper Restorals
These reporting codes are used by the communicator to transmit zone tampers and restorals for zones 1
to 32.
These reporting codes are sent to the system Tamper Alarm & Tamper Restoral call direction group of
the System.
Keypad Lockout
This reporting code is sent whenever the System enters Keypad Lockout.
This reporting code is sent to the system Tamper Alarm & Tamper Restoral call direction group of the
System.
Closing by Users 1-32, 40, 41, 42
A closing by any of these access codes will result in transmission of the corresponding reporting code.
These reporting codes are sent to the Opening and Closing call direction group of the System. This
software version will log either “Armed in Stay Mode” or “Armed in Away Mode” for this closing type.
Closing by Users 33 & 34 (Duress)
Similarly, a closing by these access codes will result in transmission of the corresponding reporting code.
These reporting codes are sent to the Opening and Closing call direction group of the System.
See also Duress Alarm Reporting Code.
Partial Closing
If programmed, this reporting code will be transmitted to the Central Station with the Closing code if there
were zones manually bypassed at the time of arming to warn of a security compromise. Automatic
bypasses caused by Stay Arming will not cause this code to be transmitted. Zones force armed by
Automatic Arming will transmit in the manner described above. If SIA is used, each zone will be
identified using the UB-XX (Untyped Bypass) identifier. The identified zones will follow the partial closing
code and precede the closing transmission.
Special Closing
If the system is closed (armed) using any of the following methods, this reporting code will be
transmitted.
Maintenance Code, Keyswitch Zone, Downloading, Quick Arm (*0), Auto Arming. This software version
will also log either “Armed in Stay Mode” or “Armed in Away Mode” for all closing types.
Opening by Users 1-32, 40, 41, 42
An opening by any of these access codes will result in transmission of the corresponding reporting code.
These reporting codes are sent to the Opening and Closing call direction group of the System.
Opening by Users 33 & 34 (Duress)
Similarly, an opening by these access codes will result in transmission of the corresponding reporting
code.
These reporting codes are sent to the Opening and Closing call direction group of the System.
See also Duress Alarm Reporting Code.
Auto Arm Cancellation