Digital Security Controls Ltd.
44
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
TROUBLE #7
DEVICE LOW BATTERY
If an RF Device reports a Low Battery signal to the panel, this trouble will be generated.
When the user enters [*][2][7] to view troubles, the following then will occur.
...... Keypad Beeps 1 time .......... Shows Zones (lights) 1-8
Press [7] ...... Keypad Beeps 2 times ........ Shows Handheld Keypads (lights) 1-4
Press [7] ...... Keypad Beeps 3 times ........ Shows Wireless Keys (lights) 1-16
Press [7] ...... Return to Zones 1-8
Note: an LCD keypad is required to view Wireless Key Low Batteries 9-16.
TROUBLE #8
LOSS OF SYSTEM TIME
When the panel is powered up, the internal time of day clock needs to be set to the correct time. This
trouble is cleared when an attempt is made to reset the internal time of day clock.
ALARM MEMORY DISPLAY
[*][3] ... When Disarmed
Press [*] then [3] to enter the alarm memory mode. The WLS9000 will prompt the alarms by Zone Number (or label
if programmed) that are in memory.
Press [#] to return to the “Ready” mode. If [#] is not pressed, the WLS9000 will time out in 30 seconds.
There is no memory of previous armed states. The Event Buffer can be uploaded to achieve this function.
DOOR CHIME ON / OFF COMMAND
[*][4] ... When Armed/Disarmed
The Door Chime feature is used to sound a tone from the keypad whenever a zone programmed as a Chime type is
activated. When the Door Chime feature is turned ON, the WLS9000 will beep several times whenever a Chime
zone is activated. This applies to both violating and restoring the zone.
If the Verbal Chime Feature is enabled, whenever a zone with the Chime attribute enabled is violated, a series of
beeps will sound and the WLS9000 will prompt:
“Zone X”
When the zone is restored, the WLS9000 will only sound a series of beeps similar to how Door Chime functions in
our current products.
If a label was programmed for the above Zone, the WLS9000 would annunciate (after the beeps):
“Back Porch Window”
…and so on.
If this option is disabled, only the series of beeps will be heard upon the violation and restore of zones that are
programmed to chime.
To turn the feature on or off, enter [*][4]. If the feature is being turned ON, the WLS9000 will prompt “Door Chime is
ON”. If the feature is being turned OFF, the WLS9000 will prompt “Door Chime is OFF”.
USER’S PROGRAMMING COMMAND
[*][5][Master Code] ... When Disarmed
The [*][5] user’s programming command is used to access User code programming.
User Code Programming
The user be prompted to enter a Master or Supervisory code. This is required to gain access to the section.
User Codes (Access Codes 1-32)