When pressed, this function key will annunciate the recorded message. If there is no message
recorded, an error tone will be heard.
8.2.17 Special Installer Functions
[901] Installer Walk Test Mode
To initiate the Walk Test Mode, enter this section, then exit Installer’s mode completely. When this mode is ON, all
zones become 24 hour non-force arm-able zones that will sound the bell (steady or pulsed attribute) for 2 seconds
and transmit their programmed alarm reporting codes when violated.
To cancel the test mode, re-enter this section. If the user attempts to arm while in Walk Test, the WLS9000 will
sound an error tone and prompt that the function is not available.
Note:
Alarm Memory is cleared upon entering Walk Test.
[902]-[903]
NOT USED
[904] Module Placement Test
The Module Placement Test of the WLS9000 is quite different from previous Power-Based products as it
incorporated the following changes and enhancements:
•
Each Detector Must pass three Consecutive Tests before being enabled on the system.
•
Each Detector is enabled in Section [202]-[205]
only
after passing the three tests mentioned above. There is no
way to manually override this enrollment process.
•
There is only “Good” and “Bad” Placements. “Fair” has been removed; it’s former status internal to the software
is considered a “Bad”.
•
The piezo will squawk once for “Good” and three times for “Bad”.
•
If the Placement is exited before all zones are properly enrolled, a General System Trouble is generated at the
keypad. This trouble can only be cleared by re-entering the Module Placement Test and testing the un-enrolled
devices.
•
Zones can be disabled via Section [202]-[205], but they cannot be enabled.
When Module Placement Test is entered, the system will annunciate all of the zones which have been enrolled on
the system, but are not enabled in Sections [202]-[205]. This allows the Placement Test to be entered after
additional devices have been enrolled on the system without the hassle or re-testing ‘placed’ zones.
As each device receives three “Good” placements, it is removed from the annunciation list and it’s corresponding bit
in Section [202]-[205] is toggled to enable the zone on the system.
[990][Installer Code][990]
Installer Lockout Enable
If enabled, the WLS9000 will give a distinctive audible indication on power up (the phone line relay will click 10
times).
This feature will have no effect on a Software Default (all programming will return to the factory defaults).
However, if a Hardware default is attempted while lockout is enabled, the default will not occur, and the fraudulent
attempt will be logged to the event buffer.
[991][Installer Code][991]
Installer Lockout Disable
This disables the Installer Lockout feature described above.
[992][Installer Code][992]
Restore Main Controller Programming
When this section is successfully entered, all programming within the Main Controller will be returned to factory
default. This does
not
include programming found in the Rx Slave uP (i.e. Serial Numbers) or in the ESCORT (i.e.
Zone descriptions, Automation programming). Section [998] and [995] may be used to perform these functions.
[995][Installer Code][995]
Restore ESCORT to Factory Default Programming