Digital Security Controls Ltd.
47
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
INSTALLER’S PROGRAMMING COMMAND
[*][8][Installer Code] ... When Disarmed
The WLS9000 is completely programmable from the Main Unit Interface using this command.
As described in Section 5.2.2, a Simple Installer’s Programming Front End Interface (the Wizard) has been added to
the WLS9000. Please see Section 5.2.2 for more information.
ARMING WITHOUT ENTRY DELAY
[*][9][Access Code] ... When Disarmed
Entering [*][9] or pressing a function key programmed for No Entry Arm before entering an access code, arms the
panel without any entry delay on the perimeter delay zones and bypasses zones that are defined as “Stay/Away”.
This command is used to arm the system while at home. When the system is armed in this mode, the “Armed” light
will be ON flashing and WLS9000 will prompt that there are zones bypassed. Once the panel is armed in this mode,
using [*][1] will remove the bypass from the “Stay/Away” zones if they were NOT manually bypassed. The [*][1]
command used here only removes the bypass from zones that have been automatically bypassed with the [*][9]
command.
Note: Delay Stay/Away and Interior Delay Zones will still have Entry Delay on a [*][9] armed panel.
QUICK EXIT
[*][0] ... When Armed
Entering [*][0] when the system is armed will allow the user 2 minutes to exit the premises through any delay zone
without altering the status of the system if the quick exit feature is enabled. After [*][0] is entered, one and only one
delay zone may be tripped. If the delay zone is left unrestored at the end of the 2 minutes, it will begin its entry delay
sequence. Any additional activity on any other active zone will cause that zone to begin its alarm or delay sequence.
Quick Exit is not designed to extend the standard Exit Delay.
ACTIVATE AUTO BYPASSED STAY/AWAY ZONES
[*][1] ... When Armed
When the system is armed in the Stay mode by arming and not exiting through a Delay zone during the exit delay or
by pressing a function key programmed for Stay Arm or Arming Without Entry Delay (*9), the zones programmed as
“Stay/Away” type zones are automatically bypassed. This [*][1] command is used to remove the automatic bypass
from these zones to fully arm the system. Once this command is executed, all “Stay/Away” type zones will become
active after the programmed Exit Delay time.