Digital Security Controls Ltd.
10
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
•
Within [*][6] User Programming under selection 7.
5.2.7 Verbal Chime
A feature has been added to the WLS9000 that allows Door Chime to annunciate the Zone that has been
violated/restored as opposed to a series of beeps.
If the Verbal Chime Feature is enabled, whenever a zone with the Chime attribute enabled is violated, a series of
beeps will sound and the WLS9000 will prompt:
“Zone X”
When the zone is restored, the WLS9000 will only sound a series of beeps similar to how Door Chime functions in
our current products.
If a label was programmed for the above Zone, the WLS9000 would annunciate (after the beeps):
“Back Porch Window”
…and so on.
If this option is disabled, only the series of beeps will be heard upon the violation and restore of zones that are
programmed to chime. If Chime is disabled via [*][4], no beeps nor prompts will be heard.
This option can be found in Section [017], Option 2, and is enabled (ON) at default.
5.2.8 Verbal Alarm
A feature has been added to the WLS9000 that provides verbal annunciation of alarm conditions on the system.
When an audible non-fire zone goes into alarm with this feature is enabled, the WLS9000 will sound the alarm
condition via the high volume piezo, but every 5 seconds (as programmed for Alarm Tone Period – Section [807],
Subsection [030])
vi
it will pause siren and the speaker an annunciate the alarm condition verbally:
“Alarm Zone 4”
or, if the label is programmed,
“Alarm South Bedroom Window”
When the zone is in alarm, the software automatically inserts the word “Alarm” in front of the appropriate zone label.
When an audible fire zone goes into alarm, the WLS9000 will sound the alarm condition via the high volume
piezo, but every 5 seconds (as programmed for Alarm Tone Period – Section [807], Subsection [030]) it
will pause siren and the speaker an annunciate the alarm condition verbally:
“Fire Alarm Zone 4”
or, if the label is programmed,
“Fire Alarm South Bedroom Smoke”
When the zone is in alarm, the WLS9000 automatically inserts the words “Fire” and “Alarm” in front of the
appropriate zone label.
In the case of multiple alarms, the WLS9000 will annunciate the first and latest zone that has gone into alarm.
Fire Zones will override Burglary Zones, similar as a Pulsing Bell will override a steady one.
This option can be found in Section [017], Option 3 and is enabled (ON) at default.
Notes: Fire annunciation always overrides any Burglary Zone alarm annunciation.
Verbal Alarm will cease with the Siren at Bell Time Out.