Digital Security Controls Ltd.
58
Private and Confidential
Installation Manual
DATE : 09/30/97
DRAFT
01
20 BPS, 1400 Hz handshake
Note: 3
rd
Phone Number follows the
02
20 BPS, 2300 Hz handshake
format of the 1
st
Phone Number
03
DTMF CONTACT I.D.
04 SIA
FSK
05
Pager
Default
04
I___II___I
1st Phone Number
04
I___II___I
2nd Phone Number
[361] ALARM / RESTORE COMMUNICATOR CALL DIRECTIONS
Default
Option ON
Option OFF
ON I___I
Option 1
1st Telephone Number
Disabled
OFF I___I
Option 2
2nd Telephone Number
Disabled
OFF I___I
Option 3-8
For Future Use
[363] TAMPER ALARM / RESTORE COMMUNICATOR CALL DIRECTIONS
Default
Option ON
Option OFF
ON I___I
Option 1
1st Telephone Number
Disabled
OFF I___I
Option 2
2nd Telephone Number
Disabled
OFF I___I
Option 3-8
For Future Use
[365] OPENING / CLOSING COMMUNICATOR CALL DIRECTIONS
Default
Option ON
Option OFF
ON I___I
Option 1
1st Telephone Number
Disabled
OFF I___I
Option 2
2nd Telephone Number
Disabled
OFF I___I
Option 3-8
For Future Use
[367] SYSTEM MAINTENANCE ALARM / RESTORE COMMUNICATOR CALL DIRECTIONS
Default
Option ON
Option OFF
ON I___I
Option 1
1st Telephone Number
Disabled
OFF I___I
Option 2
2nd Telephone Number
Disabled
OFF I___I
Option 3-8
For Future Use
[368] SYSTEM TEST TRANSMISSIONS COMMUNICATOR CALL DIRECTIONS
Default
Option ON
Option OFF
ON I___I
Option 1
1st Telephone Number
Disabled
OFF I___I
Option 2
2nd Telephone Number
Disabled
OFF I___I
Option 3-8
For Future Use
[370] COMMUNICATION VARIABLES
Default
003
I___II___II___I
Swinger Shutdown (Alarms & Rest)
(000-255 Transmissions, 000=disabled)
003
I___II___II___I
Swinger Shutdown (Tampers & Rest)
(000-255 Transmissions, 000=disabled)
003
I___II___II___I
Swinger Shutdown (Maint & Rest)
(000-255 Transmissions, 000=disabled)
000
I___II___II___I
Communication Delay
(000-255 seconds)
030
I___II___II___I
AC Failure Communication Delay
(000-255 minutes)
003
I___II___II___I
TLM Trouble Delay
(# of valid checks re3= 003-255x10s)
030
I___II___II___I
Test Transmission Cycle (land-line)
(000-255 days)/(000-255 mins)
007
I___II___II___I
Zone Low Battery Transmission Delay (000-255 days)
030
I___II___II___I
Delinquency Transmission Delay
(000-255 days/hours)
[371] TEST TRANSMISSION TIME OF DAY