To fit a new lamp:-
1. Lift the lamp into position on the right hand side of the projector and align the
PTFE sliders on each side of the lamp between the two sliders on each side of
the lamp bay in the projector.
2. Push the lamp back into the projector and secure in position by tightening the
three retaining screws.
3. Replace the side cover and test for operation.
Lamp Life Timer
The lamp incorporates a passive mercury lamp life timer. This timer has an
unmarked scalar bar which indicates 0 to 1000 hours of lamp use with graduation
marks every 50 hours. The current lamp usage is indicated by a black mark on the
the mercury bar (shown in diagram at 750 hours).
1000
HOURS
500
HOURS
0
HOURS
EÑ5
Fault Finding and Maintenance
MAINTENANCE
LBV00056; Revision A - 23/08/99