Chapter 28: Troubleshooting
231
To re-initialize (reset) the racks:
1
In the Plug-In Racks Reset dialog, click Reset to begin the
plug-in rack re-initialization.
When this step is completed, the Plug-In Racks are Ready dia-
log appears alerting you that the plug-in racks are ready to be
re-activated.
2
Click Use Racks to confirm that you want the racks to be
re-initialized. Status is shown on-screen. After the process is
complete, the console and all plug-ins are operational again.
Reset Mix Engines
Use this option to do a full system reset in one step. Reset Mix
Engines resumes all operations automatically, including the
console, settings, and plug-in racks.
To reset the Mix Engines and all operations immediately:
■
Click Reset Mix Engines in the Ready to Resume dialog.
Operations are brought back online; no further interaction is
required (no warning or confirmation dialogs appear).
More Options
Additional options are provided to clear the console, or to run
DigiTest (hardware diagnostics).
To access additional options:
■
Click More Options.
After clicking More Options, a dialog is displayed that pro-
vides the following options.
Clear Console
■
Click Clear Console to reset all D-Show parameters on all
channels to their factory default settings.
Run DigiTest
DigiTest is hardware diagnostics software for D-Show. Only
use DigiTest at the request of a Digidesign technician to diag-
nose specific hardware problems.
Restarting D-Show
If D-Show ever needs to be restarted, do the following:
To restart D-Show:
1
Turn off all power amps or turn the volume down on all
monitoring equipment.
2
Press both Reset switches on the front of the FOH Rack si-
multaneously.
If restarting the system does not correct a problem, you may
have to reset other hardware components, identify and re-
move any incompatible plug-ins, or reinstall D-Show software
using the D-Show System Restore CD.
Additional Restart Options
Additional shortcuts are provided while restarting the system,
which let you do the following:
• Back up the current show settings and clear the console. Use
this option if you suspect an auto-saved setting has become
corrupted. This lets you save your most recent settings and
clear the console without having to a full system restore.
– or –
• Restart the D-Show processor but launch into Explorer, to
manually manage software components. Use this option if
to troubleshoot the system if problems arise early in the
startup process and persist through repeated restarts.
Backup and Clear Console
To backup and clear the console at restart:
1
Start or restart the system.
2
Watch the screen closely during the startup process. As soon
as the cursor becomes visible (and before the D-Show logo
screen appears) press and hold the C key on the computer key-
board. Continue to hold the C key (do not press it repeatedly).
3
A dialog appears that lets you choose to backup your
auto-saved settings and clear the console, or to continue and
load settings normally.
Resetting the plug-in racks
Audio may be interrupted or may change levels during
this reset procedure.
Location of reset switches on FOH Rack
If you press the C key too early in the startup process, the
USB keyboard is reset instead of calling the Backup and
Clear dialog. If you do not see the backup and clear dialog,
repeat the restart process and try again.
USB
To
Control Surface
Power
Reset
FOH
Link
Reset switches
Содержание D-Show Profile
Страница 10: ...D Show Profile Guide x ...
Страница 11: ...Part I Overview and Installation ...
Страница 12: ......
Страница 16: ...D Show Profile Guide 6 ...
Страница 32: ...D Show Profile Guide 22 ...
Страница 33: ...Part II System Description ...
Страница 34: ......
Страница 50: ...D Show Profile Guide 40 ...
Страница 58: ...D Show Profile Guide 48 ...
Страница 67: ...Part III Signal Routing ...
Страница 68: ......
Страница 94: ...D Show Profile Guide 84 ...
Страница 102: ...D Show Profile Guide 92 ...
Страница 110: ...D Show Profile Guide 100 ...
Страница 134: ...D Show Profile Guide 124 ...
Страница 135: ...Part IV Processing ...
Страница 136: ......
Страница 144: ...D Show Profile Guide 134 ...
Страница 171: ...Part V Shows ...
Страница 172: ......
Страница 180: ...D Show Profile Guide 170 ...
Страница 204: ...D Show Profile Guide 194 ...
Страница 227: ...Part VI Specifications ...
Страница 228: ......
Страница 236: ...D Show Profile Guide 226 D Show Output Signal Flow Diagram Version 1 3 07 07 05 ...
Страница 245: ...Part VII Reference ...
Страница 246: ......
Страница 258: ...D Show Profile Guide 248 ...
Страница 269: ......