SIM card activation
The SIM card must be activated for cellular service. Contact your mobile service provider and see
Configuration settings and status information
There are several firmware settings for SIM cards, for selecting between dual SIM cards, designating
primary and secondary SIM cards, setting ID and phone numbers, and viewing status. See
Power cable fitting
Class 1, Div 2 units
WARNING!
Do not plug in or apply power to the unit until all connections are made to
the unit in the following steps.
For customers who have purchased a C1D2-approved unit with cable and conduit to wire into the
main power supply:
1. Ensure that the mains power to the junction box where the cable is to be wired into is off.
2. Wire the exposed end of the cable into the junction box using approved C1D2 wiring regulations
per National Electrical Code Article 501 (if located in the United States) and other regulations
applicable to the locality where it is installed.
See the following table for information on wiring this cable to the junction box. The mains
voltage for this unit needs to be between 100VAC and 240VAC, 50Hz to 60 Hz, and be able to
supply a minimum of 24 Watts.
Function
Cable Wire Color
Power Supply Phoenix Connector Pin
Number
Frame Ground (FG)
Green
1
Neutral (N)
White
2
Line (L)
Black
3
Use the blue reset button inside the unit to disconnect/reconnect power for units that are
hard-wired to power.